Description:

When opening HydraCAD, you get this error message or something similar

AutoCAD Warning

The following shortcuts in the search were invalid and ignored: \Users\AppData\Local\Microsoft\Windows\WinX\Group...

After clicking OK, HydraCAD will open up, albeit very slowly, and almost every step will take an significant amount of time, for example 45 seconds to start a new drawing or to size a pipe

 

Solutions:

Cause:

For this particular example, a learning institute was using a Sentinel Network license, they setup the master computer, imaged the disk then then cloned it to share with 80 seats.

Solution:

While unsure of the actual cause, when reviewing the HydraCAD profile in Options, the paths leading to the HydraCAD folders were using front slashes instead of back slashes.  

 

It's unknown how this was happening as the master computer had back slashes, but once imaged and opened on another computer, only the HydraCAD paths switched to front slashes.

 

Likely an issue witth the imaging software.